    Acoustic and STC-Rated Entrance Doors
    Acoustic Door Systems

    Acoustic and STC-Rated Entrance Doors

    Coordinate the complete opening around a measurable sound-control target instead of treating the door leaf as an isolated acoustic product.

    For consultants, developers, hotel teams, contractors and door distributors
    Buyer Brief

    Acoustic Performance Belongs to the Complete Opening

    STC or Rw performance depends on the tested door, frame, perimeter seals, threshold, glazing, hardware preparation and installation. A high-rated leaf cannot compensate for uncontrolled gaps or an incompatible frame.

    WONLY helps project teams define the target, review the evidence boundary and coordinate security, fire, access-control and acoustic requirements before drawings and samples are approved.

    Specification Checklist

    What Buyers Should Define Before Quotation

    Target rating

    State the required STC, Rw or project-specific criterion and the test method used by the consultant.

    Opening construction

    Confirm wall type, frame profile, clearances, threshold and interfaces that affect leakage.

    Seal system

    Coordinate perimeter seals, drop seals, meeting stiles and floor conditions for the tested configuration.

    Hardware preparation

    Review viewers, locks, closers, access control and cable routes because every penetration can affect performance.

    Conflicting requirements

    Resolve fire, egress, accessibility and security requirements without invalidating the acoustic assembly.

    Site acceptance

    Define installation tolerances, inspection steps and any field test or commissioning requirement.

    Project Workflow

    From Requirement to Delivery

    01

    Issue the acoustic target, wall build-up, opening schedule, hardware and other performance requirements.

    02

    Select a documented assembly and identify differences between the tested specimen and proposed opening.

    03

    Approve drawings, seal details, samples and installation interfaces before production.

    04

    Inspect delivery and installation, record gaps and complete the agreed site acceptance checks.

    Evidence Before Award

    What a Project Buyer Should Verify

    Test configuration matrix

    Compare the report specimen, size, frame, seals, threshold, hardware and opening direction with the proposed doorset.

    Seal-detail drawings

    Show continuous sealing at head, jambs, sill and meeting stiles, including hardware interruptions.

    Installation checklist

    Record anchors, clearances, compression and automatic drop-seal contact before handover.

    Field verification plan

    Agree visual inspection, gap measurements and any acoustic field testing before procurement release.

    FAQ

    Procurement Questions

    Is STC the same as Rw?

    No. They are different rating systems and should not be treated as numerically interchangeable without an acoustic consultant's review.

    Can a smart lock be used on an acoustic entrance door?

    Yes when its preparation, cable route and hardware remain compatible with the documented assembly and seal strategy.

    Does the laboratory rating guarantee site performance?

    No. Field performance also depends on wall interfaces, installation quality, gaps, seals and adjacent construction.

    Get Solutions & Quote

    Discuss Your Door or Smart-Entry Requirement

    Send the market, project type, quantity, opening schedule and target delivery date. Our team will identify the next technical inputs.